Tripp Lite by Eaton Isolator Series 120V 250W UL 60601-1 Medical-Grade Isolation Transformer with 2 Hospital-Grade Outlets

  • Part: 1005989
  • Model: IS250HG
$251.00

Availability

In Stock

Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEE

  • General Information
    • Manufacturer
    • Tripp Lite by Eaton
    • Manufacturer Website Address
    • https://tripplite.eaton.com/
    • Brand Name
    • Tripp Lite by Eaton
    • Product Type
    • Isolation Transformer
  • Warranty
    • Limited Warranty
    • 2 Year

  • Technical Information
    • Power Rating
    • 250 VA
    • Output Receptacle Type
    • NEMA 5-15R
    • Output Receptacle Detail
    • 2 x NEMA 5-15R
  • Power Description
    • Input Voltage
    • 120 V AC
    • Output Voltage
    • 120 V AC
    • Maximum Line Current
    • 2.10 A
  • Physical Characteristics
    • Form Factor
    • Tower
    • Height
    • 4.5"
    • Width
    • 4.8"
    • Depth
    • 7.8"
  • Miscellaneous
    • Additional Information
      • Transformer Type: Medical grade, low impedance transformer-based line isolation transformer
      • Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops
      • Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
      • Suppression Joule Rating: 680 (510 input/170 output)
      • Leakage Current: As low as 100 microamps
      • Noise Suppression Rating: 35 to 65 DB
      • Total Harmonic Distortion: Less than 1%
      • Over Current Protection: 2A circuit breaker
      • Cooling Method: Convection
      • Efficiency: 96%
      • Let-through Voltage (Ring Wave):
      • L-N: 20 V
      • L-G: 20 V
      • N-G: 0.5 V
      • Let-through Voltage (Combination Wave):
      • L-N: 250 V
      • L-G: 250 V
      • N-G: 0.5 V
    • Package Contents
      • IS250HG
      • IS250HG Isolation Transformer
      • Instruction manual with warranty information
    • Certifications & Standards
      • cUL
      • UL 2601-1
      • UL (UL Series AGIS250YWN)
    • Country of Origin
    • Taiwan
    • TAA Compliant
    • Yes